F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
D

Failure to Administer and Maintain Oxygen and Nebulizer Equipment per Physician Orders and Facility Policy

Iron County Medical Care FacilityCrystal Falls, Michigan Survey Completed on 04-17-2025

Summary

A deficiency occurred when a resident with chronic obstructive pulmonary disease (COPD), anxiety, and dementia was observed receiving supplemental oxygen at a flow rate of 3 liters per minute (L/min) via nasal cannula, despite the active physician order specifying oxygen at 2 L/min as needed. Multiple observations confirmed the oxygen was being administered at the higher rate without any documented assessment or physician notification to justify the change. The resident's medical record did not contain documentation supporting the increased oxygen flow, and the most recent vital signs indicated an oxygen saturation of 97% on room air, with no evidence of a clinical need for the higher oxygen rate. Additionally, the oxygen tubing in use was found to be dated over a month prior to the observation, exceeding the facility's protocol for changing tubing every two weeks. Staff interviews confirmed the tubing was out of date and that the protocol for timely replacement was not followed. The resident was unaware of the oxygen concentration being administered and reported feeling more short of breath recently. Further observations revealed that the resident's nebulizer equipment, including the medication chamber and mouthpiece, was left resting directly on the nightstand without a protective barrier and was not stored in a sanitary manner as required by facility policy. Staff confirmed that the nebulizer equipment should have been cleaned, dried, and stored in a plastic bag after each use, but this was not done. Facility policies for both oxygen and nebulizer care were not followed, resulting in deficiencies in both the administration and maintenance of respiratory equipment.

Plan Of Correction

The facility will ensure that residents who need respiratory care are provided such care, consistent with professional standards of practice, the comprehensive person-centered care plan, and the resident goals and preferences. For Resident #65, the DON and practitioner reviewed the resident's recent oximetry readings and assessed the resident's respiratory status, clarifying the oxygen liter flow ordered. The DON replaced, labeled, and dated the resident's oxygen tubing. The DON placed a barrier under the equipment and ensured a baggie was available to store tubing when not in use, per facility policy. The DNP reviewed the resident's record and completed an assessment with ongoing treatment for a diagnosis of COPD. No noted ill effects. On 4/17/2025, the DON identified those residents who are currently receiving oxygen and audited tubing for accuracy on labeling and to ensure correct storage units to coil and place tubing in a baggie when not in use. One of three was noted to have out-of-date oxygen tubing. The tubing was changed and labeled correctly. The DON also audited care plans for accuracy, and all three were up to date. The DON verified orders on all residents receiving oxygen to determine accuracy on the rate of flow the resident is receiving. The ADON obtained the current list of residents receiving nebulizer treatments. In each unit where these residents reside, the DON ensured nurses had proper cleaning supplies, an area to allow equipment to dry, and proper storage containers for nebulizer equipment. To prevent oxygen tubing from becoming outdated, ensure it is stored in a sanitary manner, and ensure oxygen is administered per physician order, the following has been completed and/or initiated: On 4/18/2025, the DON and ADON reviewed the following policies and deemed them appropriate with evidence-based practices: 1) Cleaning and Disinfecting Nebulizers Policy, 2) Oxygen Use and Set-up Policy, 3) Medication Administration Policy. On 5/1/2025, all nurses currently working in the facility received 1:1 education on the following: 1) Cleaning and Storage of oxygen tubing & nebulizer equipment, 2) 5 Rights of Medication Administration with a focus on checking the order to assure that oxygen is being administered at the ordered liter flow, 3) Hand Hygiene with a focus on during medication administration. For those employees who are casual/student status, on vacation, or on LOA, training will be completed before/during their next scheduled shift. The DON and ADON created a Relias education module and post-test for all licensed nursing staff, including a review of the Cleaning and Disinfecting Nebulizer Policy and Oxygen Use and Set-up Policy. The focus was on storing oxygen tubing, cleaning equipment after each use, changing oxygen tubing, and how/what to use to clean equipment. They also created a Relias education module and post-test for all CNAs, emphasizing storing tubing when not in use. 1:1 education was provided to AMA and NAA staff on the delivery of oxygen tubing and humidifier bottles, with an emphasis on: - Placing new tubing themselves and not delegating it out to another staff member. - Reapproaching the resident if unable to apply when they first attempt. - Reviewing the Oxygen Use and Set-Up Policy. To ensure the education and changes implemented are followed, monitoring has been implemented to ensure sustainability of compliance: - DON/ADON or designee will complete audits of oxygen administered per physician order and labeling of oxygen tubing for accuracy, weekly for 2 months, and with random audits for 1 month. - Storing of equipment in a sanitary manner will be audited 2 times per week for one month, weekly for one month, and randomly for one month. The facility will schedule follow-up evaluations to ensure that these practices are maintained over the long term and that any trends are addressed promptly. The DON will present a compliance report based on the audit findings to be reviewed during monthly QAPI meetings by the team for 3 months, with recommendations by QAPI for further monitoring if consistent compliance has not been achieved. The DON/ADON will be responsible for attaining and sustaining overall compliance with this plan of correction.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0695 citations
Unsecured Storage of Full Oxygen Cylinders on Nursing Unit
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Surveyors observed four full O2 cylinders on one nursing unit stored unsecured directly on the floor under a sign labeled "FULL CYLINDERS" instead of in a secured storage rack. The ADON confirmed the cylinders were full and should not be on the ground. Reference to NFPA 99 showed that freestanding cylinders must be protected from damage and properly chained or supported in a stand or cart. The DON and Maintenance Director both acknowledged that O2 cylinders are required to be stored in a secure rack, should never be on the floor, and that unsecured cylinders on the floor present a safety risk.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Handling and Storage of Oxygen Nasal Cannula
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident with severe cognitive impairment and COPD, receiving oxygen therapy via nasal cannula, was observed twice with the cannula lying on the floor beside the bed instead of stored in the bag on the oxygen concentrator as required. A CNA later picked up the cannula from the floor, wiped it with a non-disinfectant incontinent wipe, and reapplied it to the resident, despite having been trained that a cannula found on the floor should be replaced. An LVN, the DON, and the Administrator all confirmed that oxygen cannulas must be stored properly, replaced if found on the floor, and that incontinent wipes are not disinfectants, indicating a failure to follow the facility’s infection prevention and control policy.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Storage of Nebulizer Mask and Respiratory Supplies
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident with COPD and dementia, receiving scheduled nebulizer treatments, was found on multiple occasions to have a nebulizer mask stored on top of the machine rather than in a sanitary manner. A CNA and a nurse aide in training confirmed the mask’s placement, and an LPN reported that masks were routinely cleaned, dried, and then stored on top of the machine. The DON later acknowledged that masks should be washed, dried, and placed on a clean surface, and facility policy required oxygen and respiratory supplies to be stored in a plastic bag when not in use.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Oxygen Administered Without Required Physician Order
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident with acute respiratory failure with hypoxia, pulmonary hypertension, and type 2 diabetes was observed receiving oxygen at 4.5 L/min via nasal cannula without a corresponding physician order in the clinical record. The DON acknowledged that an order should have been in place before oxygen was initiated. Facility policy on supplemental oxygen via nasal cannula requires administration only under a physician or provider order, in alignment with 410 IAC 16.2-3.1-47(a)(6).

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Missing Current Physician Order for Oxygen
D
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

A resident was observed receiving O2 via nasal cannula on multiple occasions, but the chart had no current physician order for O2. The resident said she had been told after a recent hospitalization to use O2 for 30 days, but that time had passed and she was still using it because staff told her she needed it. The DON confirmed there was no current O2 order; the last order had already been discontinued.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide and Document Respiratory Care
E
F0695 F695: Provide safe and appropriate respiratory care for a resident when needed.
Short Summary

Failure to provide and document respiratory care: A resident with a trach had no documented evidence of respiratory rate, depth, and quality being monitored each shift and as needed, despite oxygen orders and trach care needs. Other residents with CPAP, nebulizer, and oxygen therapy had respiratory equipment left out of required storage, missing CPAP settings and care details in orders and care plans, and MAR entries signed by nursing staff even when respiratory staff reportedly completed the equipment changes.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙