F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
G

Failure to Provide Proper PEG Site Care and Label Enteral Feeding Equipment

Gulfport Care CenterGulfport, Mississippi Survey Completed on 06-05-2025

Summary

The facility failed to ensure proper care and monitoring of enteral feeding and gastrostomy sites for two residents. One resident, who had recently received a PEG tube prior to admission, reported that no site care had been performed and described the site as draining and unclean. Observations confirmed an old, discolored dressing with green and black purulent drainage and a foul odor, with the dressing dated several days prior. Record review and staff interviews revealed that there were no physician orders for PEG site care or monitoring for approximately 21 days after admission, and the site had not been assessed or the dressing changed as required. The resident continued to receive bolus feedings during this period, and staff confirmed the lack of orders and monitoring. Another resident receiving tube feedings was observed with a feeding bag that was not properly labeled. The bag only included the resident's last name and date, but did not indicate the time it was hung, the type of enteral feeding, or the rate. Staff interviews confirmed that the label was incomplete and did not meet facility policy, which requires the full name, rate, time and date hung, and type of feeding to be included. The family member present was also unaware of the type of enteral feeding being administered. Both residents had relevant medical histories, including recent surgical aftercare and gastrostomy status. The deficiencies were identified through observation, interview, and record review, and were confirmed by staff and facility leadership. The lack of timely physician orders, monitoring, and proper labeling of enteral feeding equipment directly contributed to the deficiencies cited.

Penalty

Fine: $26,685
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0693 citations
Incorrect G-tube Flush Volume During Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Incorrect G-tube Flush Volume During Enteral Feeding: A resident with severe cognitive impairment, aphasia, stroke, hemiplegia, and a feeding tube was observed receiving enteral feeding when an RN flushed the G-tube with 30 ml of water before and after the feeding instead of the ordered 60 ml. The RN stated he read the order wrong, and the DON and ADON confirmed the correct flush amount should have been followed.

Fine: $9,821
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Provide Ordered Hydration and Correct Tube Flushes for Enteral Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with moderate cognitive impairment, multiple comorbidities, and NPO status received nutrition and hydration via a gastrojejunal tube with orders for continuous tube feeding, 30 mL water flushes before and after medications via the gastric port, 120 mL free water flushes six times daily, and 30 mL jejunal port flushes every four hours. During observed care, an LPN administered medications and 30 mL water flushes through the gastric port but did not provide the ordered 120 mL free water flush or the 30 mL jejunal port flush, and no additional flushes were given over several hours. Later, another LPN initially attempted to give medications through the jejunal port before being redirected, and documentation on the MAR/TAR showed inconsistent flush volumes of 30–60 mL instead of the ordered 120 mL free water flushes, reflecting failure to consistently implement the prescribed hydration and port-specific flushing regimen.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Improper Head-of-Bed Positioning During Tube Feeding
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident receiving enteral tube feeding was observed lying with the HOB elevated only 15 degrees while Glucerna was infusing at 60 ml/hr. An LVN started the feeding and was unsure of the correct HOB position, and an RN stated the HOB was not elevated properly to prevent aspiration. Records showed an order to keep the HOB elevated 30-45 degrees or as tolerated and a care plan noting tube feeding related to dysphagia.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
GT Site Care and Feeding Position Not Provided as Ordered
E
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

GT site care and feeding precautions were not followed for two residents with GTs. One resident with dementia and severe cognitive impairment had a GT dressing left unchanged despite orders for daily cleansing and dressing changes, and drainage was observed at the site. Another resident was observed lying flat in a supine position while receiving continuous GT feeding, even though the CP and OSR required HOB elevation during tube feeding; RN and DON confirmed the ordered positioning was not being followed.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Expired Tube Feeding Formula Left Connected to Resident
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

Expired Tube Feeding Formula Left Connected to a Resident: A resident with anoxic brain damage, dysphagia, and a gastrostomy tube was observed with an enteral feeding pump off but still connected and a tube feeding bag that staff said had exceeded the 24-hour limit after opening. Staff confirmed the formula was no longer safe after 24 hours, and the facility policy required accurate labeling and dating of each feeding bag or formula container.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incorrect Enteral Feeding Formula Administered Contrary to Physician Order
D
F0693 F693: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.
Short Summary

A resident with an order for Glucerna 1.2 at a specified rate and duration was instead observed receiving Isosource at 60 ml/hour. Record review confirmed the physician’s order for Glucerna 1.2, while observation and interview with an LPN verified that Isosource, a different enteral formula, was being administered. The DON later stated that the LPN should have verified the physician’s order before administering the tube feeding.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙