F0759 F759: Ensure medication error rates are not 5 percent or greater.
E

Medication Error Rate Exceeds 5% Due to Improper Administration and Documentation

South Heritage Health & Rehabilitation CenterSaint Petersburg, Florida Survey Completed on 10-15-2025

Summary

Surveyors identified that the facility failed to maintain a medication error rate below 5%, with observations revealing a 68.18% error rate during medication administration to two residents. During medication passes, staff administered incorrect medications, failed to follow manufacturer instructions for insulin administration, and did not adhere to facility policy regarding hand hygiene and documentation. Specifically, one LPN used an insulin syringe to extract insulin from a pen, contrary to manufacturer warnings and facility policy, due to a lack of appropriate pen needles. The same staff member also administered a probiotic that was not the one ordered and failed to notify the physician about late or missed medications. Another LPN was observed administering multiple medications late, failing to perform hand hygiene or wear gloves when administering eye drops, and documenting that a resident received medication that was actually refused. Additionally, scheduled doses of inhaled medications and topical treatments were not administered as ordered, and documentation did not reflect accurate administration times or refusals. Interviews with staff confirmed that medication administration was delayed due to staffing issues and meetings, and that there had been an ongoing shortage of insulin pen needles, which had not been adequately addressed by facility leadership. Review of facility policies showed clear requirements for medication administration timing, hand hygiene, and proper use of insulin pens, none of which were consistently followed. The DON and other staff acknowledged the lack of pen needles and the resulting improper insulin administration practices, as well as gaps in communication with pharmacy and among staff. The pharmacy confirmed a recent shortage of pen needles, but the facility had not implemented alternative solutions or ensured compliance with safe medication administration practices.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0759 citations
Insulin Administration Errors and Failure to Prime Insulin Pens
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified that the facility exceeded the acceptable medication error rate when two residents with type 2 DM received insulin doses that were not administered according to orders or manufacturer instructions. In two separate observations, an LPN administered Novolog and another LPN administered insulin glargine and insulin lispro without priming the insulin pens, and the insulin lispro and Novolog were given after the residents had already consumed a significant portion of their breakfast meals, despite orders for administration before meals. Manufacturer information for both insulin products required priming before each injection to ensure accurate dosing, and facility policy required medications, including insulin, to be administered safely, timely, and in accordance with prescriber orders and specified time frames.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Ensure Accurate Medication Dosage Identification During Medication Pass
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility failed to maintain medication error rates below 5% when an LPN, during a medication pass for a resident receiving Metamucil for constipation and a cranberry supplement for UTI prevention, was unable to identify the correct dosages for these ordered medications. Despite a policy requiring adherence to the rights of medication administration, including the right dose, the LPN reported that the orders should have been clarified to specify the exact dose, indicating medications were being prepared and administered without clear dosage understanding and contributing to an overall medication error rate above the acceptable threshold.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Maintain Acceptable Medication Error Rate and Proper Medication Timing
E
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors found that the facility did not maintain a medication error rate below 5%, identifying multiple late and improperly timed medication administrations and a missing medication. A medication aide gave a cholesterol medication and wound-healing supplements significantly later than their scheduled times, and another aide administered acetaminophen well outside the ordered time window and could not obtain a prescribed dose of Ingrezza because it had not arrived from the pharmacy. An LPN administered fast-acting Humalog insulin before a meal when no food was available and was unaware of the required timing of insulin in relation to meals, while the facility’s insulin policy lacked guidance on meal-related timing despite manufacturer instructions specifying administration within 15 minutes before or immediately after eating.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Above 5% Due to Incorrect Dosing and Insulin Pen Technique
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified a medication error rate of 7.41%, exceeding the 5% threshold, involving two residents and two LPNs. In one case, a resident with dementia and hypertension received 5 mg of donepezil instead of the 10 mg dose ordered. In another case, a resident with DM2 received insulin lispro via a KwikPen that was not primed, and the LPN held the dose knob for only about 2 seconds instead of the manufacturer-recommended 5 seconds. The DON reported that staff had not been educated on proper insulin pen priming, and facility policy requires verification of the correct medication and dose before administration.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Administration Errors and Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

Surveyors identified an 11.1% medication error rate when an LPN did not administer a resident’s ordered nifedipine ER dose because it was not available in the cart or pyxis, and proceeded with the rest of the medications. In a separate instance, an RN administered furosemide despite the order having been discontinued and gave magnesium oxide instead of the ordered SlowMag, explaining that he relied on scanning multi-drug packets rather than individually verifying each medication against the MAR, and knowingly substituted magnesium oxide when SlowMag was unavailable.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Medication Error Rate Exceeded Due to Unavailable Ordered Medications
D
F0759 F759: Ensure medication error rates are not 5 percent or greater.
Short Summary

The facility failed to keep its medication error rate below 5% when a resident with dementia, COPD, diabetes, and depression did not receive ordered doses of Singulair and calcium/vitamin D3 because the medications were not available at the time of administration. An RN attempted to pass the morning medications but was unable to administer these two ordered drugs, and later confirmed their unavailability, resulting in two errors out of 33 medication opportunities and an overall error rate of 6.06%.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙