F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
D

Failure to Monitor IV Placement and Tourniquet Removal by Contracted Provider

Dublin Post AcuteDublin, Ohio Survey Completed on 03-04-2026

Summary

The deficiency involves the facility’s failure to ensure adequate supervision and monitoring following IV insertion by a contracted provider for one resident. The resident was admitted with diagnoses including syncope, generalized muscle weakness, cognitive communication deficit, and expressive language disorder, and was assessed as cognitively intact but requiring maximal assistance with most ADLs. A hospital discharge summary indicated IV fluids were to be discontinued and oral intake encouraged. On admission, nursing obtained orders for lab work due to dehydration concerns, and later, at the request of the resident’s POA, the DON obtained an order for PRN IV fluids and contacted a contracted IV company to place an IV line. Documentation from the contracted company showed IV line placement was completed and signed off at a specific time, but the medical record contained no immediate post‑procedure nursing assessment to verify removal of the tourniquet or evaluate the IV site. A late entry nursing note documented that the POA was concerned about hydration and that an IV team placed an IV line; the note stated the tourniquet was not removed prior to administering IV fluids and that another nurse later observed the tourniquet still in place and removed it. A subsequent nursing note documented that an IV was placed in the left arm, IV fluids were started, and that the resident’s daughter requested assessment of the arm, which was found to be swollen with a tourniquet still on the upper arm. The tourniquet was removed, the arm was elevated, and a cold compress was applied. The facility’s self‑reported incident and investigation did not specify the exact time of IV placement, the time swelling was identified, or the duration the tourniquet remained in place, and contained conflicting statements about how long the tourniquet was left on. Interviews revealed there was an expectation that staff assess IV sites after outside companies place lines, but no defined requirement for immediate post‑placement assessment. The Administrator acknowledged that the facility could not determine the timeframe the tourniquet remained on, had no documentation of when post‑placement assessment occurred until surveyor intervention, and had not provided education or information to the contracted company related to this event. An RN reported that after the contracted company completed the IV placement, he received verbal handoff, entered the room, and removed a tourniquet he observed, and then, after the resident’s daughter raised further concern, he reentered the room and removed a second tourniquet from the upper arm, noting slight swelling and applying a cold compress. He also stated that management was not notified of the arm’s condition until his next scheduled shift, and there was no documented evidence of timely monitoring by facility staff following the IV placement.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0689 citations
Failure to Control Razors, Sharps, and Chemical Wipes Creating Accident Hazards
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Surveyors found that the facility failed to keep the environment free of accident hazards when a resident’s room contained an unattended shaving razor on the sink and additional razors in a nightstand, despite leadership stating razors were not permitted in resident rooms. An LPN disposed of unused lancets in regular trash instead of a sharps container, contrary to acknowledged policy. On two occasions, an unattended housekeeping cart on an upper floor had germicidal wipes left on top and easily accessible, even though housekeeping leadership and staff stated that chemicals and disinfectant wipes were to be kept locked in the cart for safety.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Assess Safe Use of Lift Reclining Chair
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident with severe cognitive impairment, dementia, a history of falls, and dependence on staff for transfers was observed using a lift reclining chair even though the care plan and physical device review did not identify that device. Therapy staff lowered the chair and placed the remote next to the call light on the resident’s lap, and staff stated they were not aware of any formal assessment for safe use of the lift chair. The DON stated the resident should have had an assessment to determine whether she was safe to have the lift chair.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Follow Transfer and Sling Size Interventions
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident with severe cognitive impairment, dementia with behavioral disturbances, and fall risk interventions in place was transferred by staff using methods that did not match the care plan and Kardex. Staff used a transfer belt for some transfers, then later used a Hoyer lift from mattresses on the floor to a wheelchair, but used a green sling even though the resident required a yellow sling based on weight. The RN, LPN, DON, and PT verified the resident’s transfer status and sling instructions were not updated to reflect current needs.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Complete Required Quarterly Smoking Safety Assessments
D
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

A resident with nicotine dependence was care planned as a smoker who could go out to smoke at designated times or with family, with an intervention that a smoking evaluation be completed quarterly. The last documented smoking safety evaluation showed the resident could safely smoke with supervision, but no additional evaluations were completed for several months, contrary to facility policy requiring smoking assessments at admission, readmission, with significant change, and quarterly by a licensed nurse, even though the resident continued to smoke under staff and family supervision in the courtyard.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Supervise Smokers and Secure Smoking Materials
J
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Failure to supervise smokers and secure smoking materials. Surveyors found that 27 smokers were not adequately monitored and that residents were able to keep cigarettes and lighters in their possession despite care plan directions to return them after smoking. One resident with severe cognitive impairment, dementia, schizophrenia, and continuous oxygen use was observed with cigarettes and a lighter while on oxygen, and staff confirmed she was an unsafe smoker requiring direct supervision.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Code Alert System Failed to Prevent Resident Elopement
J
F0689 F689: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
Short Summary

Code Alert System Failed to Prevent Resident Elopement: The facility failed to keep the code alert system functioning as intended and did not follow the manufacturer’s weekly testing and inspection guidance. Two residents with significant cognitive impairment were able to get through the main doors, and one resident exited the building before staff followed outside. The report also states that multiple residents with code alert devices did not have adequate elopement or wandering assessments and care plan interventions, and several attempts to leave were not documented in the record.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙