F0909 F909: Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.
D

Loose Bed Rail Not Securely Attached

Perimeter Rehabilitation Suites By HarborviewAtlanta, Georgia Survey Completed on 03-19-2026

Summary

The facility failed to ensure a siderail was securely attached to the bed for one resident. The facility policy titled, Side Rail Safety, required regular inspection of the mattress and bed rails for entrapment areas and for bedrails to remain correctly installed without shifting or loosening over time. The resident involved was admitted with multiple sclerosis, other lack of coordination, seizures, generalized muscle weakness, cognitive communication deficit, and major depressive disorder. The care plan documented limited physical mobility related to repeated falls, multiple sclerosis exacerbation, history of seizures, weakness, and rib fractures, with staff to provide supportive care and assistance with mobility as needed. The resident's quarterly MDS showed multiple sclerosis, depression, seizures, upper and lower extremity impairments on one side, and a need for moderate assistance with rolling and sitting to standing, while also indicating a BIMS score of 15 out of 15. During observation, the resident's right-hand mid-bed metal rail was loose and unable to remain in the proper location; the resident lifted the rail and let it fall to the floor, stating he used it to hold on to while turning in bed. A CMT confirmed the rail was loose and posed a risk for injury. The Maintenance Director later inspected the rail and found it attached with one bolt near the head of the bed, and when lifted, it dropped to the floor. The facility was unable to provide documentation of weekly bed inspections completed by maintenance.

Penalty

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Resources

Below are regulatory guidelines relevant to this citation:

See other F0909 citations
Failure to Inspect and Assess Bed Rails and Bed Systems for Entrapment Risk
D
F0909 F909: Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.
Short Summary

Surveyors found that the facility did not conduct or document regular inspections or entrapment assessments of bed frames, mattresses, and bed rails, despite FDA guidance and manufacturer instructions requiring ongoing evaluation of hospital bed systems. Three residents with CVA, hemiplegia, cognitive impairment, and significant ADL dependence had quarter or half side rails in use, but therapy notes, care plans, and MDS assessments did not consistently reflect side rail use or any entrapment evaluations. Staff interviews revealed that the maintenance engineer only addressed side rails when reported broken, a RN was unaware of any side rail safety or inspection procedures, and a PT described routine admission of brain-injured residents with side rails and lap belts while indicating that nursing was responsible for bed safety zoning. The facility’s restraint policy addressed assessment and consent for positioning and safety devices but did not include any schedule or process for device inspection.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Incompatible Mattress and Bedframe for Dependent Resident
D
F0909 F909: Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.
Short Summary

A resident with severe cognitive impairment and multiple neurologic and vascular diagnoses was observed on multiple occasions lying on an air mattress that was too small for the bedframe, resulting in the resident’s feet and head extending beyond the mattress and a gap of about one foot between the mattress and the bedframe. A CNA, the ADON, and the DON each confirmed that the mattress did not properly fit the bedframe and did not accommodate the resident’s height.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Missing Bed Entrapment Assessment and Incomplete Bed Inspection Logs
E
F0909 F909: Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.
Short Summary

The facility failed to complete a bed entrapment assessment before a resident used bilateral upper bed rails and failed to document monthly inspections for all beds in use. A resident who had capacity to make decisions and needed partial/moderate assistance with mobility was observed using elevated side rails, and RN and Maintenance staff confirmed the rails were in use and that maintenance was responsible for the zone assessment. The February bed safety checklist did not show the required entrapment measurement for that resident, and the monthly bed maintenance log listed only a few rooms rather than all resident beds.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Bed Rail Inspection and Compatibility Deficiency
D
F0909 F909: Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.
Short Summary

Bed Rail Inspection and Compatibility Deficiency: The facility did not ensure regular entrapment inspections of bed systems for two residents using bilateral bed assist bars. Staff used a bed system measurement device that was missing a required scale component, did not retain test documentation, and were not following the bed manufacturer's specifications for compatible replacement rails. One resident had dementia, osteoporosis, and muscle weakness with impaired cognition, and another resident had MS and sepsis with substantial assistance needs for bed mobility.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Inspect Bed Side Rails
D
F0909 F909: Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.
Short Summary

The facility failed to regularly inspect bed frames, mattresses, and side rails for four residents with diagnoses including fracture, COPD, autism, seizures, dementia, falls, spinal stenosis, MS, heart failure, and acute respiratory failure with hypoxia. Observations showed both half side rails upright and moving with minimal effort, and the medical records showed no maintenance inspection for the side rails. The DON said maintenance had not completed any inspections, the maintenance staff said the rails were placed when nursing requested and had not been inspected, and the Administrator expected side rail inspections at least quarterly.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.
Failure to Regularly Inspect Bed Rails and Bed Frames
D
F0909 F909: Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.
Short Summary

Regular inspection of bed frames, mattresses, and bed rails was not conducted for two residents with bilateral upper quarter bed rails in use. One resident was observed in bed with the rails up, another stated she uses the rails if she needs to hold onto them and that staff use them, and the Maintenance Supervisor said staff only tighten loose bolts and do not keep logs of the work.

No penalty information released
tooltip icon
The penalty, as released by CMS, applies to the entire inspection this citation is part of, covering all citations and f-tags issued, not just this specific f-tag. For the complete original report, please refer to the 'Details' section.

Know what gets cited — and walk into your next survey with full visibility

We process and analyze inspection reports and Plans of Correction using AI to surface insights and trends — so you can improve care quality and stay ahead of compliance risk before your next survey.

Get ready for your next survey

See what surveyors are citing in your state and spot your risk areas before they do.

Monthly Citation Reports

Have you been cited for this tag?

Save hours drafting a compliant Plan of Correction — AI built on real approved POCs.

Plan of Correction Writer

Trusted data from CMS and state health departments

Every citation, penalty and Plan of Correction is sourced from public CMS records (latest release June 24, 2026) and official state health department websites — never guesswork.

Trusted by long-term care providers and associations.

Allegria Senior Living logo
FHCA logo
WeCare Centers logo
Care Rehab logo
An unhandled error has occurred. Reload 🗙